Corrosion mapping · Lévis
Corrosion mapping in Lévis
Corrosion mapping locates the zones where reinforcing steel is likely corroding in a concrete slab or wall, so that repairs can be targeted in Lévis. A useful map separates structures near the river from those exposed to road salt.
Lévis
Working in Lévis
In Lévis, a structure on the riverbank and a parking slab on the plateau do not face the same conditions, and the measurement grid is designed accordingly. State the structure’s exposure, the repairs already made and the portions that can be cleared. If the structure is in a heritage area or a constraint zone, a repair planned from the map will need a permit: build it into the schedule.
In Lévis, a permit is required at all times for a property in a heritage area, subject to a PIIA or in a constraint zone, such as soil with low bearing capacity. Two interim control by-laws, adopted in the spring of 2025, also restrict new permits in the areas served by the Saint-Nicolas and Desjardins wastewater treatment plants.
Preparing your project in Lévis
- Describe the structure’s exposure: waterside, de-icing salts or both
- Locate repairs already made so they appear on the grid
- Plan for the permit required for the repairs that follow the map
From the Lauzon shoreline to the plateau, building stock that followed the river, then the road
The Lauzon seigneury was created in 1636, but the land along the river was poorly suited to farming: eel fishing came first, while Saint-Nicolas, Saint-Jean-Chrysostome and Pintendre grew through agriculture. In the early 19th century, every cove on the shoreline was used to store and process timber bound for England, and mills and shipyards settled on the banks still available. Captain Allison Davie’s ship repair yard, founded in 1829, is presented by the City as the oldest shipbuilding industry in the country.
The town of Lévis was born from a charter assented to on May 18, 1861, and well-to-do families built their homes on the heights, away from the working shoreline. The Quebec Bridge, inaugurated in 1919 after two collapses during construction, then the Pierre-Laporte Bridge, opened in 1972, came with the post-war population boom: economic and commercial activity moved from the riverfront to the plateau, along the main highways.
That growth has a downside. The City states that the Desjardins and Saint-Nicolas wastewater treatment plants have reached capacity, and two interim control by-laws adopted on March 24, 2025 restrict new construction or renovation permits in the areas they serve. Elsewhere, a permit is required at all times in a heritage area, under a PIIA or in a constraint zone, for example on soil with low bearing capacity.
A structure near the river and a parking ramp along the plateau’s main roads do not face the same attacks. For a corrosion map, describe what the structure goes through: moisture and freeze-thaw cycles by the water, de-icing salts in a parking garage or on an access lane. A grid surveyed and properly recorded becomes a point of comparison if a second pass is planned after repairs.
Measuring corrosion activity
The ASTM C876 test method covers the estimation of the corrosion potential of uncoated reinforcing steel in concrete, for the purpose of determining its corrosion activity. Taken on a grid, these measurements produce a map of the surveyed surface.
Exposed slabs and parking garages
Parking garages are subject to specific obligations in Quebec: an annual visual verification and an in-depth verification report by an engineer every five years, according to the Régie du bâtiment du Québec. A corrosion map helps locate the zones to watch between these verifications.
- On a cracked or spalled parking slab
- Before planning concrete repairs
- To monitor an area that has already been repaired
Mapping method, process and limitations
How potential measurements work, how the survey runs, how to read the maps and their limitations are covered on our corrosion mapping in Quebec page. To find where the rebar is before measuring, see our concrete scanning page. This page only covers what is specific to Lévis.
Frequently asked questions
Does corrosion mapping indicate the strength of the structure?
Not directly. It provides information on the corrosion activity of the rebar; assessing structural capacity is an engineer’s responsibility.
Why combine it with a concrete scan?
Ground-penetrating radar locates the rebar and estimates its depth, which helps position corrosion measurements on the steel.
Can a map be used to plan repairs?
Yes, that is its most common use: it helps the engineer delimit the areas to investigate or repair. It does not set the extent of the work on its own, which remains a professional decision.
Does a map need to be redone after repairs?
It is not mandatory, but a second pass on the same grid lets you compare before and after. It assumes the grid and method of the first survey were properly recorded.
Sources
- ASTM C876-22b, Standard Test Method for Corrosion Potentials of Uncoated Reinforcing Steel in Concrete
- Régie du bâtiment du Québec: Parking garages, maintenance and inspection
- Ville de Lévis: Permis de construction et rénovation (in French)
- Ville de Lévis: Règlements à caractère provisoire sur les projets de construction (in French)
- Ville de Lévis: Histoire de Lévis (in French)
- Ville de Lévis: Permis de construction et rénovation (in French)
- Ville de Lévis: Règlements à caractère provisoire sur les projets de construction (in French)

Contact
Your project starts here.
Tell us about your needs. Our team supports you with rigour and precision, wherever you are in Quebec.