Skip to main content
438-815-6942info@scanaxis.ca
ScanAxis

Corrosion mapping · Terrebonne

Corrosion mapping in Terrebonne

Corrosion mapping locates the zones where reinforcing steel is likely corroding in a concrete slab or wall, so that repairs can be targeted in Terrebonne. On a parking slab that has been repaired before, the map has to place every repair.

Terrebonne

Working in Terrebonne

Parking areas and ramps in Terrebonne’s commercial districts, built along the main roads, take de-icing salts. Before a corrosion map, state where repairs have already been made and of what type: readings taken around a repaired area are easier to understand when it appears on the grid. If the structure belongs to a building in the heritage site, a repair that changes its appearance will need authorization.

Old Terrebonne has been a heritage site declared by the Quebec government since the order in council of May 2026. In this area, authorization from the Ministère de la Culture et des Communications is required before changing the appearance or layout of a building, or excavating the ground, even inside a building, on top of the steps taken with the City.

Preparing your project in Terrebonne

  1. Mark earlier repairs and their type on a drawing
  2. Give the sections that can be closed and when
  3. State whether the building is part of the Old Terrebonne heritage site

From seigneurial village to boulevards, building stock split between old and new

The village of Terrebonne took shape from 1720, when seigneur Louis Lepage de Sainte-Claire had a grist mill and a sawmill built and granted the first town lots. Simon McTavish, the leading partner of the North West Company, acquired the seigneury in 1802 and built a dam to increase the mills’ water power; Joseph Masson and Marie-Geneviève-Sophie Raymond later expanded the Île-des-Moulins complex. The village became a town in 1860.

Part of Terrebonne was destroyed by fire in 1922. Autoroute 25, inaugurated in 1965, replaced rue Chapleau and the Sophie-Masson bridge as the main link to Montreal, and boulevard des Seigneurs, opened in 1967, drew the shops that had been on rue Saint-Pierre. Left behind, Old Terrebonne was revitalized from the 1970s through heritage classifications, restorations and housing that fits the old fabric, such as the Terrebourg complex.

Through Order in Council 745-2026 of May 20, 2026, the Quebec government declared Old Terrebonne a heritage site, an area of about 25 hectares with some 200 buildings dating from the 18th century onward, spread across Bas-de-la-Côte, Île des Moulins, the institutional core and rue Saint-Louis. In a declared heritage site, authorization from the Ministère de la Culture et des Communications is needed before changing how a building is laid out, repairing or changing its appearance, or excavating the ground, even inside a building.

Structures tied to the main roads opened in the 1960s and parking areas in commercial districts take de-icing salts winter after winter. For a parking slab or a ramp, say whether repairs have already been made and where: a corrosion map that places repaired areas on the grid avoids misreading the measurements taken around them.

Measuring corrosion activity

The ASTM C876 test method covers the estimation of the corrosion potential of uncoated reinforcing steel in concrete, for the purpose of determining its corrosion activity. Taken on a grid, these measurements produce a map of the surveyed surface.

Exposed slabs and parking garages

Parking garages are subject to specific obligations in Quebec: an annual visual verification and an in-depth verification report by an engineer every five years, according to the Régie du bâtiment du Québec. A corrosion map helps locate the zones to watch between these verifications.

  • On a cracked or spalled parking slab
  • Before planning concrete repairs
  • To monitor an area that has already been repaired

Mapping method, process and limitations

How potential measurements work, how the survey runs, how to read the maps and their limitations are covered on our corrosion mapping in Quebec page. To find where the rebar is before measuring, see our concrete scanning page. This page only covers what is specific to Terrebonne.

Frequently asked questions

Does corrosion mapping indicate the strength of the structure?

Not directly. It provides information on the corrosion activity of the rebar; assessing structural capacity is an engineer’s responsibility.

Why combine it with a concrete scan?

Ground-penetrating radar locates the rebar and estimates its depth, which helps position corrosion measurements on the steel.

Does a repaired area distort the measurements?

It can change the readings around it. That is why it must be placed on the grid: the interpretation takes it into account instead of mistaking it for an active area.

Can a parking garage be mapped while still open?

Yes, by closing sections in turn. The phasing is decided before the first pass so the portions join up on the final map.

Downtown Montreal skyline and the Jacques Cartier Bridge at dusk

Contact

Your project starts here.

Tell us about your needs. Our team supports you with rigour and precision, wherever you are in Quebec.