Concrete scanning uses ground-penetrating radar (GPR) to help locate rebar, conduits and other embedded items before coring, drilling or cutting a slab, wall or column. ScanAxis offers this non-destructive service in Quebec. Findings help the project team plan work while accounting for the limits of detection.

Request a quote
ScanAxis ground-penetrating radar on a concrete slab

How concrete scanning works

An antenna moves across the surface and records electromagnetic reflections at material boundaries. Interpretation helps estimate the position and depth of detectable items. GPR can collect data from one accessible face.

A scan complements available drawings. It does not guarantee that every object will be found or authorize cutting reinforcement.

Slab scanning and rebar detection

Openings for plumbing, ventilation or anchors can intersect rebar, conduits or post-tensioning tendons. Scanning helps the project team review the proposed opening locations.

Rebar orientation, spacing and estimated depth can inform further assessment. Structural capacity and conformity require appropriate interpretation.

Detecting voids beneath slabs

A gap between a ground-supported slab and its support may produce a detectable reflection. Detectability depends on size, depth and whether the bottom of the slab is readable.

An anomaly alone does not identify its cause or the required repair. Additional investigation may be needed before filling or reconstructing the affected area.

A void under the slab and a delamination within its thickness both sound hollow, yet they do not call for the same repair. The distinction is developed on the voids beneath slabs and concrete delamination page.

What can be detected

Detection depends on site conditions.

What can be detected
TargetPossible findingsLimits
Rebar and tendonsAlignment and estimated depthDense reinforcement may mask deeper items.
Metal conduitsReflections from embedded conduitsExact type and contents may remain uncertain.
Non-metal conduitsDepends on contrast and contentsSmall empty conduits may be missed.
Slab bottom and voidsIf the interface is readableMoisture, depth and rebar affect visibility.
Fine cracksNo guaranteed reliable detectionAnother test method may be needed.

Use cases by project type

Concrete scanning is most useful when work must pass through or anchor into existing concrete. The situations below are common. The exact survey scope still depends on each site.

A heated slab raises one more question, since the heating occupies the same thickness as the reinforcement. What that changes is developed on the radiant floor heating and heating cables page.

  • Commercial renovation

    Locate rebar and conduits before opening a slab for plumbing, electrical or ventilation work in a refitted space.

  • Industrial building

    Identify embedded items at the planned locations for machine, racking or guardrail anchors.

  • Parking and structural slabs

    Prepare coring, cutting or local repairs while accounting for rebar and, where present, post-tensioning tendons.

  • Structures without current drawings

    Document detectable elements when drawings are missing, incomplete or no longer reflect existing conditions.

GPR survey methodology

GPR sends a short electromagnetic pulse into the concrete. When it meets a material with different properties, such as steel, a conduit or air, part of the energy returns to the antenna. On the recorded profile, a bar crossed at a right angle usually appears as a hyperbola whose apex marks its estimated position.

Depth is calculated from the signal’s travel time and the wave velocity in the material. Velocity varies with moisture and concrete composition, so depths remain estimates that can be refined using a known thickness or an existing opening.

Antenna selection involves a trade-off: a higher frequency generally provides better resolution near the surface, while a lower frequency reads deeper with less detail.

How a GPR survey worksSchematic, not to scale. Left: concrete cross-section. Right: the profile recorded by the GPR.12345
  1. Antenna moved across the surface in the scan direction
  2. Rebar shown in cross-section
  3. Embedded conduit
  4. Bottom of slab, where the interface is readable
  5. Hyperbola apex: estimated bar position on the profile

Schematic, not to scale. Left: concrete cross-section. Right: the profile recorded by the GPR.

  1. Scoping

    Define planned openings, the survey area, available drawings and the expected deliverable.

  2. Data collection

    Scan the cleared surface in parallel passes, in one or two directions depending on the question.

  3. Interpretation

    Read the profiles to estimate the position and depth of detectable items.

  4. Reporting

    Deliver results in the agreed format: marking, photographs, sketches or a report.

When to request a scan

Describe the planned work to define the survey area.

  • Before coring for plumbing, ventilation, electrical work or sampling
  • Before cutting an opening (door, window, hatch, stairway)
  • Before anchoring heavy equipment, racking or guardrails
  • Before drilling post-tensioned slabs
  • Before partial demolition of a structure
  • To locate radiant floor heating or a pipe before repairs

Preparing the survey and using the findings

Provide the location, drawings, planned openings and access conditions. Agree on the required marking, photographs, sketches and report in the scope of work.

Post-tensioned slabs require particular care. A scan alone does not authorize drilling; the work must be reviewed by the parties responsible for the site and structure. Prestressing, strands and ducts are set out on the post-tension, prestressing strands and ducts page.

GPR limitations

Dense reinforcement, metal surfaces and wet concrete may reduce readability. Depths are estimates, and no detected indication does not prove an area is clear.

Read all findings together with their assumptions and limitations. Antenna selection and complementary tests depend on the investigation objective.

Verifiable facts

Information you can check.

The methods, regulatory framework and contact details shown here link to public sources. No review or certification is displayed without verification.

  • Technical references

    The methods described on this site are presented in these public references.

  • Regulatory framework

    The Régie du bâtiment du Québec oversees the maintenance and verification of parking garages.

    RBQ
  • Areas served

    Surveys offered in these Quebec cities:

    • Montreal
    • Laval
    • Longueuil
    • Quebec City
    • Gatineau
    • Sherbrooke
    • Trois-Rivières
    • Saguenay
    • Drummondville
  • Direct contact

    Reach the ScanAxis team by phone or email.

Frequently asked questions

How long does a concrete scan take?

Duration depends on area, the number of locations, access and reinforcement complexity. Include the planned openings and schedule in your request.

Can GPR detect PVC conduits?

It may detect them when there is enough contrast with the concrete. Diameter, contents and depth affect readability; small empty conduits may be missed.

Do both sides of a wall need scanning?

GPR can work from one accessible face. Data from the other side may be useful depending on thickness and reinforcement density.

Does scanning replace structural drawings?

No. It provides complementary observations, including for undocumented structures, subject to the method’s limitations.

Does GPR pose a risk to occupants?

GPR emits low-power radio waves and does not use ionizing radiation, unlike industrial radiography. It therefore does not require the protective measures associated with radiography. Site access and safety instructions are still agreed with the property manager.

How deep can GPR read?

Useful depth depends on the antenna, concrete moisture and reinforcement density. A higher frequency shows near-surface items in more detail, while a lower frequency reads deeper with less precision. Feasibility is confirmed based on the element’s thickness and the survey objective.

How are findings shown on the concrete?

Depending on the assignment, detected items can be marked on the surface, photographed or recorded on a sketch. Specify the format in your request, especially if drilling takes place days after the survey and marking may fade.