Structural assessment · Lévis
Structural assessment in Lévis
Structural assessment evaluates the condition of a concrete structure with non-destructive test methods, before a repair, an alteration or a regulatory verification in Lévis. On soil with low bearing capacity, what the engineer needs to know about the structure is decided before the survey.
Lévis
Working in Lévis
Lévis lists soil with low bearing capacity among its constraint zones, where a permit is required at all times. For an extension or an added storey in such an area, the engineer may need the foundation thickness, whether rebar is present and the condition of the concrete before reaching a conclusion. Name the engineer in the request and state the decision the report must inform, so the survey covers what is useful and nothing more.
In Lévis, a permit is required at all times for a property in a heritage area, subject to a PIIA or in a constraint zone, such as soil with low bearing capacity. Two interim control by-laws, adopted in the spring of 2025, also restrict new permits in the areas served by the Saint-Nicolas and Desjardins wastewater treatment plants.
Preparing your project in Lévis
- Name the engineer who will use the report and the decision expected
- State whether the land is in a constraint zone according to the City
- Gather the available drawings and earlier inspection reports
From the Lauzon shoreline to the plateau, building stock that followed the river, then the road
The Lauzon seigneury was created in 1636, but the land along the river was poorly suited to farming: eel fishing came first, while Saint-Nicolas, Saint-Jean-Chrysostome and Pintendre grew through agriculture. In the early 19th century, every cove on the shoreline was used to store and process timber bound for England, and mills and shipyards settled on the banks still available. Captain Allison Davie’s ship repair yard, founded in 1829, is presented by the City as the oldest shipbuilding industry in the country.
The town of Lévis was born from a charter assented to on May 18, 1861, and well-to-do families built their homes on the heights, away from the working shoreline. The Quebec Bridge, inaugurated in 1919 after two collapses during construction, then the Pierre-Laporte Bridge, opened in 1972, came with the post-war population boom: economic and commercial activity moved from the riverfront to the plateau, along the main highways.
That growth has a downside. The City states that the Desjardins and Saint-Nicolas wastewater treatment plants have reached capacity, and two interim control by-laws adopted on March 24, 2025 restrict new construction or renovation permits in the areas they serve. Elsewhere, a permit is required at all times in a heritage area, under a PIIA or in a constraint zone, for example on soil with low bearing capacity.
The plateau was mostly built during the post-war expansion, while Old Lévis keeps far older middle-class homes. For an extension, an added storey or a change of use, state the known construction period and the work already done. In a constraint zone, such as soil with low bearing capacity, the engineer may need the thickness of foundations and slabs before reaching a conclusion: have it written into the scope.
Non-destructive test methods
The American Concrete Institute report ACI 228.2R-13 reviews non-destructive test methods for in-place concrete, including visual inspection, stress-wave, magnetic and electrical methods, infrared thermography and ground-penetrating radar.
Parking garages in Quebec
In Quebec, the Building chapter of the Safety Code requires parking garage owners to carry out a visual verification every year and, every five years, to obtain an in-depth verification report from an engineer. Non-destructive surveys can document the condition of the concrete in support of these verifications.
- Before repairing or strengthening a slab
- Before a change of use or an alteration
- When monitoring a parking garage
- After cracks or spalling appear
Assessment methods, process and limitations
Complementary methods, how the survey runs, what the report contains and what an assessment does not replace are covered on our structural assessment in Quebec page. To locate rebar and conduits before coring, drilling or cutting, see our concrete scanning page. This page only covers what is specific to Lévis.
Frequently asked questions
Does a structural assessment replace an engineer’s opinion?
No. Non-destructive tests provide data on the condition of the concrete; structural interpretation and recommendations are an engineer’s responsibility, as the Safety Code provides for parking garages, for example.
Which structures can be assessed?
Usually reinforced concrete slabs, walls, columns, beams and parking garages, in commercial, industrial, institutional or residential buildings.
Can the assessment evaluate the bearing capacity of the soil?
No. It documents the concrete of the structure: thickness, rebar, anomalies. Soil capacity is a matter for a separate geotechnical study, which the engineer can order in parallel.
Why attach earlier inspection reports?
They locate the areas already observed and let the survey focus on what remains to be documented. They also help compare the current condition with past findings.
Sources
- American Concrete Institute, ACI 228.2R-13, Report on Nondestructive Test Methods for Evaluation of Concrete in Structures
- Régie du bâtiment du Québec: Parking garages, maintenance and inspection
- Ville de Lévis: Permis de construction et rénovation (in French)
- Ville de Lévis: Règlements à caractère provisoire sur les projets de construction (in French)
- Ville de Lévis: Histoire de Lévis (in French)
- Ville de Lévis: Permis de construction et rénovation (in French)
- Ville de Lévis: Règlements à caractère provisoire sur les projets de construction (in French)

Contact
Your project starts here.
Tell us about your needs. Our team supports you with rigour and precision, wherever you are in Quebec.